Documents

ABB, AC31 Programmable Controllers I/O-Modules

Description
Main catalogue Serial data converters ILPH range Serial data converters In the field of industrial data transmission, various processes of data transmission and interfaces are used today. Already existing systems need to be updated or connected to new devices for continuity of process. When new communication functions are not build-in, ABB propose a range of converters to be able to use from the standard RS232 or RS485, to the Ethernet open products or the Optical Fiber. Ethernet communicat
Categories
Published
of 13
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Related Documents
Share
Transcript
  Main catalogue Serial data converters ILPH range   1 N07001 060209 RS-232RS-485RS-232RS-232RS-422RS-422RS-422RS-422RS-232 RS-232RS-232RS-232RS-232 RS-232RS-232 15 mmax.1.2 kmmax.15 mmax.1.2 kmmax. TCPRS-232RS-485Modbus / RTUModbus / TCP 1SNC 116 001 C0202 Serial data converters In the field of industrial data transmission, various processes of data transmission and interfaces are used today. Already existing systems need tobe updated or connected to new devices for continuity of process. When new communication functions are not build-in, ABB propose a range ofconverters to be able to use from the standard RS232 or RS485, to the Ethernet open products or the Optical Fiber.Ethernet communication is now one of the main features need in open communication, ABB propose the e-ILPH to connect the serial devices to theweb world. Uses  Adaptation : The use of converters allows the connection of two devices using differentinterfaces.To add new equipment to existing installations. Galvanic Isolation : To protect sensitive equipment it is sometimes necessary to use converterswhich allow galvanic isolation. Type of connection Immunity to noise RS232 LowRS422 HighRS485 HighCL HighOF Very highEthernet High To cross a disturbed environment : Some interfaces are more sensitive to noise. Electrically, it is preferable, insome cases, to change the interface or support. Multipoint connections : Some equipments are only designed to communicate in RS232 point to pointconnection. To communicate with several devices it is then necessary to useconverters RS232 to RS422, RS485, CL or OF to reach multipoint mode. Type of connection Connection RS232 Point to pointRS422 12 pointsRS485 32 pointsCL 5-6 pointsOF 32 pointsEthernet Point to point or multipoint Type of connection Max. distances * RS232 15mRS422 1.2kmRS485 1.2kmCL 300-500mOF 4kmEthernet 100 m with CAT5 cable Increase in the transmission and amplification distan-ces of the signals : Every connection has its own limits, to increase the communication distan-ces you only have to change the type of link (converter) or amplify the signal(Repeater) using an ILPH. * Depending on transmission speed.Example :Example : Line 1Line 2Power ConverterRepeaterExample :Example :Example : Noisyelements RS-485 2-/4 wires World Wide communication : Communication is more and more used with Ethernet support. The interestsare to have a distant access, to use an already existing network and toupload information and data on a supervisor or a computer. The conver-sions from serial to Ethernet protocol are used to connect local network toEthernet. Protocol conversion : Modbus is one of the main protocols used in the industrial networks. Thecreation of Modbus/TCP allows an adapted access to the Ethernet network.So, the conversion between these 2 protocols is necessary.Example :Example :  2 N07002 060209 ã ãã ãã ãã ãã ãã ãã ãã ãã ãã ãã ãã ãã ãã ãã ãã ãã ãã ã 1SNA   684 234   R 20 001SNA   684 244   R 02 001SNA   684 231   R 25 001SNA   684 233   R 27 001SNA   684 333   R 23 001SNA   684 334   R 24 001SNA   684 202   R 01 001SNA   684 236   R 22 001SNA   684 237   R 23 001SNA   684 238   R 04 001SNA   684 239   R 05 001SNA   684 212   R 22 001SNA   684 232   R 26 001SNA   684 246   R 04 001SNA   684 247   R 05 001SNA   684 248   R 16 001SNA   684 249   R 17 001SNA   684 252   R 02 00 RS232RS422 / RS485 RS485RS232 / RS485      R    S    2    3    2     R    S    4    2    2     /      R    S    4    8    5    2    4      V      D    C    2    4  -    4    8      V      D    C    1    1    0  -    2    4    0      V     A    C    2    4  -    4    2      V     A    C    /     D    C     E    t     h   e    r    n   e    t      1     0   -     3     4       V      D     C ,       1     0   -     2     4       V     A     C 1SNC 116 001 C0202      I    n   s    u     l   a    t     i   o    n     *     P   a    r    t     n    u    m     b   e    r   s    C     L    O     F  -    S    O     F  -     P  3 N07012 060209 ILPH RS 232-RS 485 / Ethernet 1 0,12 ILPH RS 232 - 485 / Ethernet +24V0V24VTXTXGNDRXRXB1+B2- M        J         H        G          M      L         K       D    E    A GNDRXTX Ethernet LINKTXDRXD    e  -    I    L    P    H     S    P    E    E    D PWR     A    C    T    I    V    I    T    Y     M    L    K          J         H        G          M      L         K    4   3   2  1    O   N    4   3   2  1    O   N    5   6   7   8 KLDE A 1SNC 116 001 C0202 Serial data converters ILPH Range Power supply 1  Voltage 10...34 V DC, 10...24 V AC Voltage tolerance -10%, +10%Consumption 2 W maxConnections coding screw removable connector 0 to 2,5 mm² (22-14 AWG) Power supply 2  Voltage 10...34 V DC Voltage tolerance -10%, +10%Consumption 2 W maxConnections screw connector (AWG 20) Serial link 1 : RS 232 EIA RS 232Overvoltage protection integratedBaud rate / Transmission distance max. 115,2 kbits/s / max. 15 mConnections 2,5 mm² screw connector (AWG 20) or male SubD 9 points Serial link 2 : RS 485 EIA RS 485Overvoltage protection integratedLine polarization integratedEnd line resistance integratedBaud rate / Transmission distance max. 115,2 kbits/s / max. 1200 mConnections coding screw removable connector 0 to 2,5 mm² (22-14 AWG) Ethernet link Overvoltage protection integratedBaud rate / Transmission distance 10-100 Mbits/s / max. 100 m without Hub or Switch with CAT5 cableConnections RJ45 connector Traffic indication   Voltage 1 yellow LEDStatus of signal 3 green LED (RxD, TxD, LINK), 2 amber or green LED (Speed, Activity) EMC behavior  Electrostatic discharge EN 61000-4-2Radiated electromagnetic field EN 61000-4-3Burst EN 61000-4-4Surge EN 61000-4-5Electromagnetic compatibility EN 55022 Other characteristics  Galvanic isolation betweenserial link / power supply / Ethernet link 750 VDC / 1500 VACConfiguration of the operating mode using internal switches or/and software (TELNET or HYPERTERMINAL)Operating temperature 0°C ... +60°CStorage temperature -20°C ... +70°CMounting any requiredDIN rail fixing (EN 50002) snap-on mountingWire size 2,5 mm² / stranded with ferrule, 4 mm² solidDimensions (W x D x H) 94 x 22,5 x 100 mmWeight 120 gSerial data convertere-ILPH Description Type Order P/N Packaging Weight kg Technical data Power supply Power supply 2Power supply 1 center of rail Isolated RS232 or/and RS485 to Ethernet converterTriple galvanic isolationRS232 on SUBD 9 points or screw connectorsRS485 on removable screw connectorsEthernet 10/100 Mbit/s, RJ45 connectorPower supply 10-34 VDC et 10-24 VACPossible to have a redundant 10-34 VDC power supplyEconomic with low consumptionUp to 100m with CAT5 cable without Hub or SwitchGood EMC characteristicsUp to 2 Modbus®\TCP Masters  Available modes:Modbus®\TCP to Modbus® RTU conversionTransparent Client or Server modeSMTP mode (Mail send)Standards: TPC/IP, TELNET, DHCP, FTPSpecifics functions in Modbus® protocol:Concentrator (Asynchronous mode) up to 1200 wordsAC31 programmingModbus® Easy Net mode : this mode could be used to exchangedata without a Modbus®/TCP master. The data are logged in a tableand could be distributed to one or all the others e-ILPH participantson Ethernet. SubD9connector pin 2 = RXpin 3 = TXpin 5 = GNDpin 7 = RTS   1SNA   684 252   R 02 00

Sensors

Aug 18, 2017
Search
Tags
Related Search
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks