Documents

DS- MCS.xls

Description
Engineering Consultancy Services for developing Integrated Terminal Automation Solution for IOCL Instrument Specification for MCS Module : Standard Data sheets Doc No.312286-FDS-TAS-DS-01-200 Sub Module Name: MCS Doc No.312286-FDS-TAS-DS-01-217 Rev: 1 Page No.1 DATA SHEET MASTER CONTROL STATION FOR MOVs Indian Oil Corporation Limited Mott MacDonald Pvt Ltd. Marketing Division – Head office Oil, Gas and Petrochemicals (India) Indian Oil Bhavan 44/45, Street No. 14, G-9-Ali Yavar Jung
Categories
Published
of 7
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Related Documents
Share
Transcript
  Indian Oil Corporation LimitedMott MacDonald Pvt Ltd. Marketing Division – Head office Oil, Gas and Petrochemicals (India)Indian Oil Bhavan44/45, Street No. 14,G-9-Ali Yavar Jung Marg, Bandra, EastMIDC, Andheri (East),Mumbai 400 051 Mumbai – 400093, India. Engineering Consultancy Services for developing Integrated Terminal Automation Solution for IOCLInstrument Specification for MCS Sub Module Name: MCSDoc No.312286-FDS-TAS-DS-01-200Page No.1Rev: 1Module :  Standard Data sheets Doc No.312286-FDS-TAS-DS-01-217 DATA SHEETMASTER CONTROL STATION FOR MOVs  Issue and Revision Record: IOCL Project No. DescriptionApproved By MMPL Project No. INDIAN OIL CORPORATION LTD312286 Sub Module Name: MCSDoc No.312286-FDS-TAS-DS-01-217Rev: 1 Checked By MASTER CONTROL STATION FOR MOVs Client DATA SHEET RevDatePrepared By115/01/13SATHVSJSD  Page No.2 Instrument Specification for MCSEngineering Consultancy Services for developing Integrated Terminal Automation Solution for IOCL Module :  Standard Data sheets Doc No.312286-FDS-TAS-DS-01-200  SHEET NO012341X2X3X4XDESCRIPTIONREVISIONTITLEDATECover Sheet Of MCSCover Sheet Of MCSIndexData sheet Of MCS IOCL DOC. NO. Engineering Consultancy Services for developing Integrated Terminal Automation Solution for IOCLInstrument Specification for MCS  INSTRUMENT DATA SHEETMCS MMCI Doc NoSHEET NO. RevCLIENTPROJECTIOCL Doc No SL NO 123456789101112131415161718192021  All necessary mounting accessories like sliding rail, fastners, cable ties, power adapters etc.10 % to 90 % (non condensing)VTA In Kgs H x W X D mm (Vendor to Specify)0°C to +55°CCommunication between Master Station and the actuatorsFor redundant applications, two identical Master Stations shall be implemented in redundant configuration.The Master Systems shall monitor each other; in the event of failure of one Mast Station, the redundant Master Station shall automatically take over.Master Station redundancy(Hot-Standby)Modbus TCP/IP Data transfer via Ethernet, 10 Base-T, or 100 Base-T (IEEE 802.3) Connecti RJ-45 plug at the front panel Communication in Mosbus data format via TCP/IP protocols TC address VTA – Standby StationVTA – Master StationHousing for integrated touch screen for installation in 19“ racks Below are the minumum data interface from actuator  Output data Operation commands from the Master Station to the actuators – OPEN, STOP, CLOSE, Position setpointInput data Feedback signals from the actuators to the Master Station- End position OPEN, CLOSED- Actual position value- Selector switch in postion LOCAL/REMOTE- Running indication (directional)- Torque switch OPEN, CLOSED- Limit switch OPEN, CLOSED- Motor thermoswitch tripped- Torque fault tripped before resching end position- Motor single phasing 312286-FDS-TAS-DS-01-2174  ActuatorsEnclosure protection Ambient temperatureIP 20 1IOCL312286 Housing Engineering Consultancy Services for developing Integrated Terminal Automation Solution for IOCL DESCRIPTION Loop RedundancyPower and wattageModelQtyData interface to the actuatorsUser Interface (HMI)Nos. of Actuatrors / loop & per MCSMounting AccessoriesHumidityWeight (Approx.)DimenssionsMaster Control Station (MCS) TypeUser Interface functionCommunication between Master Station and the TAS-PLCMake DATA SHEET MASTER CONTROL STATION FOR MOV ACTUATORS VTA - Vendor to adviceVTA1 Lot   User Interface shall cover:- Operation and setting of the Master station and the actuators connected- Status feedback of the Master Station as well as of the actuators connectedOperation and monitoring using integrated Touch Screen: LCD/LED Screen- 262 k colours possible - Visible screen: 10.4“ panel - Resolution: 640 X 480 pixels As minimum AC current 230 V AC, 48-65 Hz, Power consumption: VTAMaster Station for controlling Open Protocol MODBUS actuators via Modbus RTU Protocol / Data transfer via RS-485,  Active bus termination at the ends of the RS-485 cable segmentsWith use of Twisted, screened copper cable according to IEC 61158Coupling and uncoupling of actuators during opeartion shall be possibleUse of internationally standardised fieldbus protocols / VTASetting the communication parameters via the user interface / VTAModbus RTU / Open Protcol Field Bus line/loop topology Available baud rate: 9600, 19200, 38400Cable length: Without repeater max. 1.2 Km, with repater approx. 10 kmNumber of actuators per loop: Without repeater max. 32/loop for MCS having 3 loops total 96 OR 120 nos. per MCS for MCS having one loop.MCSRedundant line topology to the actuators by an additional, redundant interface within the Mast StationRedundant loop topology to the actuators by an additional, redundant interface within the Mas  Actuators with open protocol suitable for connection to the Master Station.
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks