Documents

IWCF practice questions

Description
IWCF practice questions
Categories
Published
of 95
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Related Documents
Share
Transcript
  Stack Configuration 1. Using the BOP configuration shown below answer the following questions.a. With drillpipe in the hole, is it possible to shut the well in under pressure and repair the side outlets on the drilling spool?A. Yes B. No b. With no drill pipe in the hole, is it possible to shut the well in under pressure and repair the drilling spool?A. Yes B. Noc. Is it possible to shut the well in with drill pipe in the hole and circulate through the drill pipe?A. Yes B. No d. With drill pipe in the hole, and the well shut in under pressure with the annular preventer, is it possible to circulate through the kill line and chokeline? A. Yes B. Noe. With no drillpipe in the hole, is it possible to shut the well in under pressure using the annular preventer and change pipe rams to blind rams?A. Yes B. Nof. While replacing the ring gasket on the drilling spool choke line flange the well starts to flow. There is no drill pipe in the hole. Can the well be shut in under  pressure?A. Yes B. No  2. Using the BOP configuration shown below answer the following questions.a. With no drill pipe in the hole, is it possible to shut the well in under pressure and repair the side outlets on the drilling spool?A. Yes B. No b. With no drill pipe in the hole, is it possible to shut the well in under pressure and repair the drilling spool?A. Yes B. Noc. Is it possible to shut the well in with drill pipe in the hole and circulate through the drill pipe?A. Yes B. Nod. While changing blind rams to pipe rams with drill pipe in the hole the wellstarts to flow. Can the well be shut in?A. Yes B. No e. With no drill pipe in the hole, is it possible to shut the well in under pressure and change the pipe rams? A. Yes B. Nof. With drill pipe in the hole, is it possible to shut the well in under pressure and change blind rams to pipe rams?A. Yes B. No  3. Using the BOP configuration shown below answer the following questions.a. With the well shut in under pressure on 5” drillpipe in the hole, is it possible to repair the side outlets of the drilling spool?A. Yes B. No b. With no drillpipe in the hole, is it possible to shut the well in under pressure and change the 3-1/2” rams to 5” rams?A. Yes B. Noc. With the well shut in on 3-1/2” rams (on 3-1/2” pipe) under pressure, and with a safety valve in the string, is it possible to change 5” rams to variable bore rams?A. Yes B. Nod. With the well shut in on 5” pipe rams under pressure, is it possible to change blindrams to 5” pipe rams?A. Yes B. Noe. With the well shut in on 5” pipe rams under pressure, can the annular element be replaced?A. Yes B. Nof. With the well shut in on 5” pipe rams under pressure, can the manual valve on the choke line be replaced?A. Yes B. No  4. Using the BOP configuration shown below answer the following questions.

Letter to Women

Jul 23, 2017

TSO Primer

Jul 23, 2017
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks