  Handbook  Edition 04/2005 - Revision 04 Order no.: FDK-521H0723 SFIDK.PS.027.W4.02 SITRANS F M MAGFLO ®®®®® Electromagnetic flowmeters Sensor types MAG 1100, MAG 3100, MAG 5100 W Transmitter types MAG 5000, MAG 6000  s []   Technical Documentation (handbooks, instructions, manuals etc.) on the complete productrange SITRANS F can be found on the internet/intranet on the following links:English: http://www4.ad.siemens.de/WW/view/en/10806951/133300  SFIDK.PS.027.W4.02 SITRANS F M MAGFLO ® Siemens Flow Instrumentsrange of electromagneticflowmeters 2 MAG 1100MAG 1100MAG 3100MAG 3100 WMAG 5100 WFOOD Size [mm] DN 2-100DN 10-100DN 15-2000DN 25-1200DN 25-1200 Connection FlangelessWeld-in adapter,FlangeFlangeFlange(Sandwich design)clamp adapter,thread adapter Pressure [bar] Max. 40Max. 40Max. 100Max. 40Max. 40 Temperature [ °°°°° C]  − 20 to 200  − 30 to 150  − 40 to180  − 10 to 95  − 5 to 90 Liner Zirconium oxideCeramic (Al 2  O 3 ),Neoprene, EPDM,Neoprene andDN 25-40 &(Z r 0 2 )PFATeflon (PTFE),EPDMDN 350-1200Ceramic (Al 2  O 3 ), Ebonite,hard elastomer PFALinatex ® DN 50-300composite elastomer Electrodes PlatinumPlatinumAISI 316 Ti,AISI 316 Ti,AISI 316 Ti,Hastelloy C276HastelloyHastelloy C,PE electrodesPE electrodesPlatinum/Iridium, Titanium,Tantalum,PE electrodes Enclosure IP 67IP 67IP 67/IP 68IP 67/IP 68IP 67/IP 68 Ex-version EEx [ia] [ib] IIB T4-T6EEx e ia IIC T3-T6EEx d [ia] [ib] IIB T4-T6MAG 5000MAG 6000 Outputs 1 current output1 current output1digital output1digital output1 relay output1 relay output Flow direction Uni/bidirectionalUni/bidirectional Communication OptionalAdd-on modulesHART ® Display 3 lines3 lines20 characters20 characters(optional without display)(optional without display) Meter uncertainty  ± 0,5% o.r.  ± 0,25% o.r. Enclosure  IP 67, IP 20 IP 67, IP 20 Custody transfer PTBPTB approval (cold water)OIML R75OIML R117 Ex-version [EEx ia] IIC[EEx ia ib] IIB Safety barrier 19 [EEx ia] IIC Power supply 12-24 V AC/DC12-24 V AC/DC115-230 V AC115-230 V AC Batch NoYesMAG 6000 IndustryMAG 8000 W Refer to Operating manualOperating manualSFIDK.PS.026.E1.02SFIDK.PS.026.D2.02   3 SITRANS F M MAGFLO ® SFIDK.PS.027.W4.02 1.1 Product introduction................................................................................................................................................. 41.2 Mode of operation .................................................................................................................................................... 51.3 Pressure Equipment Directive 97/23ECs ................................................................................................................. 61.3.1 Exclusions ............................................................................................................................................................... 71.3.2 Product marking....................................................................................................................................................... 72.1 Sensor MAG 1100 and MAG 1100 Ex ..................................................................................................................... 82.2 Sensor MAG 1100 FOOD ........................................................................................................................................ 92.3 Sensor MAG 3100, MAG 3100 Ex and MAG 3100 W ............................................................................................ 102.4 Sensor MAG 5100 W - updated 2005.10.21.......................................................................................................... 122.5.1 Transmitter MAG 5000 (DN 6 to DN 1200) - updated 2005.06.13.......................................................................... 132.5.2 Transmitter MAG 6000 - updated 2005.06.13........................................................................................................ 142.5.3 Safety barrier (ia/ib) DN ≤  300 ............................................................................................................................... 152.5.4 Safety barrier (ia) DN ≥  350 ................................................................................................................................... 152.5.5 Cleaning unit .......................................................................................................................................................... 152.6 Meter uncertainty - updated 2006.03.15 ............................................................................................................... 162.7 Output characteristics MAG 5000 and MAG 6000 ................................................................................................. 172.8.1 Sensor cables and conductivity of medium ........................................................................................................... 182.8.2 Minimum accept data for cable .............................................................................................................................. 182.9 HART ®  communication add-on module .................................................................................................................. 182.10 Cable data (Supplied by Siemens Flow Instruments)............................................................................................ 183.1 Sizing table (DN 2 to DN 2000) .............................................................................................................................. 193.2.1 Minimum conductivity............................................................................................................................................. 203.2.2 Liner selection guide .............................................................................................................................................. 203.2.3 Electrode selection guide ...................................................................................................................................... 203.3 Installation conditions ............................................................................................................................................ 203.4 Cleaning unit .......................................................................................................................................................... 243.5 Custody transfer approval ..................................................................................................................................... 253.6 Transmitter MAG 5000 CT, MAG 6000 CT Sealing.................................................................................................. 253.7 Ex survey according to Directive 94/9/EC (ATEX)................................................................................................. 263.8 Approvals............................................................................................................................................................... 274.1 Sensor MAG 1100.................................................................................................................................................. 284.2 Sensor MAG 1100 FOOD ....................................................................................................................................... 294.3 Sensor MAG 5100 W - updated 2006.03.15 .......................................................................................................... 324.4 Sensor MAG 3100 and MAG 3100 W..................................................................................................................... 344.5 Transmitter ............................................................................................................................................................. 355.1 Potential equalization............................................................................................................................................. 375.2 Inlet protection MAG 3100 ..................................................................................................................................... 395.3 Cathodic protected piping ...................................................................................................................................... 396.1 Compact installation MAG 5000 and MAG 6000 .................................................................................................... 406.2.1 Add-on modules MAG 6000 only............................................................................................................................ 426.2.2 Remote installation. At the sensor ......................................................................................................................... 426.2.3 Remote installation. Wall mounting......................................................................................................................... 436.2.4 Remote installation. Transmitter in 19 insert ......................................................................................................... 456.2.5 Add-on modules MAG 6000 only............................................................................................................................ 466.2.6 Installation in IP 66 wall mounting enclosure ......................................................................................................... 476.2.7 Installation in IP 65 panel mounting enclosure (front of panel).............................................................................. 486.2.8 Installation into the back of a panel ...................................................................................................................... 496.3 Transmitter Safety barrier ...................................................................................................................................... 506.4 Transmitter Cleaning unit........................................................................................................................................ 517.1 Transmitter MAG 5000 and MAG 6000 connection diagram ................................................................................... 527.2 Wiring diagram for transmitter and sensor ............................................................................................................. 538.1 Keypad and display layout..................................................................................................................................... 578.2 Menu build-up......................................................................................................................................................... 588.2.1 Password ............................................................................................................................................................... 588.3.1 MAG 5000 and MAG 6000 - Menu overview .......................................................................................................... 598.3.2 MAG 5000 CT and MAG 6000 CT - Menu overview................................................................................................ 608.4.1 Basic settings........................................................................................................................................................ 618.4.2 Outputs .................................................................................................................................................................. 628.4.3 Digital and relay outputs ........................................................................................................................................ 628.4.4 Relay outputs......................................................................................................................................................... 638.4.5 External input......................................................................................................................................................... 638.4.6 Sensor characteristics........................................................................................................................................... 648.4.7 Reset mode............................................................................................................................................................ 648.4.8 Service mode ......................................................................................................................................................... 658.4.9 Operator menu setup ............................................................................................................................................. 668.4.10 Product identity ..................................................................................................................................................... 678.4.11 Change password .................................................................................................................................................. 678.4.12 Language mode ..................................................................................................................................................... 688.4.13 HART ®  communication MAG 5000 HART or as add-on module.............................................................................. 688.5.1 Flow rate ................................................................................................................................................................ 698.5.2 Totalizer ................................................................................................................................................................. 698.5.3 Batch ..................................................................................................................................................................... 698.6.1 Settings available .................................................................................................................................................. 708.6.2 Dimension dependent factory settings MAG 5000 and MAG 6000 ........................................................................ 718.6.3 Dimension dependent batch and pulse output settings ......................................................................................... 718.6.4 MAG 5000 CT and MAG 6000 CT settings............................................................................................................. 728.7.1 Error handling......................................................................................................................................................... 738.7.2 List of error numbers ............................................................................................................................................. 749.1 Transmitter check list............................................................................................................................................. 759.2 Trouble shooting MAG transmitter .......................................................................................................................... 769.3 Check list MAG sensor .......................................................................................................................................... 779.4 Coil resistance table .............................................................................................................................................. 7810. Please look on our homepage http://www.siemens.com/flow  under Product Selector ...................................... 79 2.Technical data1.Product introduction3.Project guidance4.Dimensions and weight6.Installation of transmitter5.Installation of sensor7.Electrical connection8.Commissioning10.Ordering9.Service    T  e  c   h  n   i  c  a   l   d  a   t  a   S  e  n  s  o  r   C  o  m  m   i  s  s   i  o  n   i  n  g   O  r   d  e  r  -   i  n  g   D   &   W   I  n  s   t  a   l   l  a   t   i  o  n  o   f  s   i  g  n  a   l  c  o  n  v .   E .  c .   P  r  o   j  e  c   t  g  u   i   d  a  n  c  e  4 SITRANS F M MAGFLO ® SFIDK.PS.027.W4.02All SITRANS F M MAGFLO ®  electromagnetic flowmeters feature a unique SENSORPROM  ®  memory unit which stores sensor calibration data and transmitter settings for the lifetime of theproduct.At commissioning the flowmeter commences measurement without any initial programming. 1.1Product introduction1. Product introduction SITRANS F M MAGFLO ®  electromagnetic flowmeters offer reliable, precise and inexpensiveflow measurement on all electrically conductive liquids. Typical applications are found in allindustries. E.g.:ãWater sector:Potable water, treatment of chemicals, waste water and sludge.ãFood sector:Dairy products, beer, wine, soft-drinks and fruit juices.ãChemical sector:Detergents, pharmaceuticals, acids and alkalies.ãOther sectors:District heating, paper pulp and mining slurries.SITRANS F M MAGFLO ®  electromagnetic flowmeters are characterised by simplicity: ⇒ Simple to install ⇒ Simple to commission ⇒ Simple to operate ⇒ Simple to maintainSITRANS F M MAGFLO ®  electromagnetic flowmeters are manufactured by Siemens FlowInstruments A/S - one of the worlds leading makers of flowmeters.The factory settings matching the sensor are storedin the SENSORPROM  ®   unit. Also customer specifiedsettings are downloaded to the SENSORPROM  ®  unit. Should the transmitter be replaced, the newtransmitter will upload all previous settings andresume measurement without any need for re-programming.Furthermore, the fingerprint used in connectionwith the Siemens Flow Instruments Verificator isstored during the sensor calibration. USM II Plug & Play add-on communicationmodules. USM II - the U niversal S ignal M odule with Plug &Play simplicity makes it easy to access and integratethe flow measurement with almost any system. Itensures the flowmeter will be easy to upgrade to newcommunication platforms in the future, too.
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks