School Work

TBE222

Description
for review
Categories
Published
of 8
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Related Documents
Share
Transcript
  CLIENTPROJECTSITE KEY   X PACKAGE TITLE: TAG NUMBER: V1010 A/B/CREQN. NUMBER: ? S.No.UNITS 1.0GENERAL 1401010MAP90235/BD/001?FMC Technologies?National Oilwell Varco ? ?To be confirmed?To be confirmed? ?To be confirmed?To be confirmed? ?To be confirmed?To be confirmed? ?To be confirmed?To be confirmed? ?To be confirmed?To be confirmed? ?To be confirmed?To be confirmed? ?To be confirmed?To be confirmedü ?To be confirmed?To be confirmed? 2.0 2.1? ASME SEC VIII Div 1ü ASME SEC VIII Div 1ü barg75 and Full VacuumüYes?To be confirmedü °CMinus(-50)/60üYes?To be confirmedü To S-A00-1351-001?To be Confirmed?To be confirmedü To S-A00-1351-001?To be Confirmed?To be confirmedü To S-A00-1351-001?To be Confirmed?To be confirmedü To S-A00-1351-001?To be Confirmed?To be confirmed RequiredüProvided?Not Provided 2.2m3/hr Oil Inlet Densitykg/m3Oil Inlet Viscosity cPWater Inlet Flowratem3/hr Water Inlet Densitykg/m3cPm3/hr kg/kmolcPm3/hr m3/hr m3/hr ptbkg/m3µm 2.3 °Cbarg°Cbargbargmm mmmm 1119.53Gas ViscosityGas Outlet Flow Rate10.0310% of liquid flow rate20.490.015 @ 88 bargVTAVTAVTA TECHNICAL BID EVALUATION SUMMARY INLET SEPARATOR   FMC TechnologiesNational Oilwell Varco  ASME SEC VIII Div 1/2 SPECIFICATION REQUIREMENTS 612.387.710.24414.64 Conformance to Process Engg.Flow Scheme-Inlet Separator Conformance to Packaged Equipment General Design Philosophy and SpecificationProvision of Documents as per SDRL DESIGN REQUIREMENTSMechanical Design Relavent P&IDsCodeDesign PressureDesign TemperatureWind Load designBlast Load DesignTransportation Loading Design All other loadingsMechanical datasheet by Vendor  Process Design Oil Inlet Flowrates Design Data Water Inlet Viscosity Gas Inlet Flow RateGas Molecular WeightWater Outlet Flow RateOil Outlet Flow RateParticle LoadingParticle Average DensityParticle Range5 to 64200010 to 150Operating TempratureOperating PressureDesign Temprature (Min / Max)Design Pressure (Min / Max)Test PressureCone HeightS-A00-135A-001Number of LinersDiameter (ID)Cylinder Height-15 to 25.569 to 88-50 / 60FV / 105VTAVTAVTAVTAVTA DESCRIPTION Quotation Ref. / DateVessel manufacturer Conformance to Inlet Separator Mechanical Spec.Conformance to Pressure Vessel Gen.Design Philosophy &SpecConformance to Inlet Separator DatasheetConformance to Basic Engineering Design Data  Doc No.: 247581721.xls.ms_office10/15/2014Page 1 of 8  CLIENTPROJECTSITE KEY   X PACKAGE TITLE: TAG NUMBER: V1010 A/B/CREQN. NUMBER: ? S.No.UNITS TECHNICAL BID EVALUATION SUMMARY INLET SEPARATOR FMC TechnologiesNational Oilwell VarcoSPECIFICATION REQUIREMENTSDESCRIPTION mmmmmmm3 Turndown 3.0CONSTRUCTION Vessel Dimensions ?1800 : 4600?1700 : 4500? Vessel Thickness(Shell/Head)mmü64 / 56ü56 / 54ü Post Weld Heat TreatmentüYesüYesü External PaintingAs per Data Sheet & Spec?YesüYesü Internal CoatingNot RequiredüüInternal clad /overlay with SS316L upto wetted height of vesselm As per Data Sheet üUpto 2.1 m height-OKX 1.5 m not sufficient-Min. Upto 2.1 m height required. Anode Provision against galvanic corrosion ?To be confirmed?To be confirmedü Provision of ext. attachments-cleats, pipe supports etcüYesüYesü 2:1 HeadsAs per Data Sheet & SpecüConfirmed?2:1 SE Head Skirt heightmm As requiredü2000?Not Provided Skirt ring height?Not Provided?Not Provided 4.0MATERIALSVessel Shell / Head platesüSA516 70N + 316L OLüSA516 70N + 316L OLü Internals/attachmentsSS316LüSA516 70N + 316L OLüTo be Confirmedü Flange BoltingSA 320 Gr.L7/SA 194 L7?To be ConfirmedüTo be Confirmedü Fluoro Carbon Coating for flange boltsAs per datasheet?To be ConfirmedTo be ConfirmedNozzle FlangeSA350 Gr LF2üSA182F316LTo be ConfirmedNozzle PipeSA333 Gr 6üSA312TP316L (D<10 )SA516 70N + 316L OL (D 12 & Larger)To be ConfirmedPipe fittingsSA420 WPL 6üSA403WP316LSA403WP316LExternal attachmentsSA 516 Gr. 70 NSA516 70N + 316L OL (Direct Welded)Carbon Steel (Indirect Welded)SA516 70N + 316L OL (Direct Welded)Carbon Steel (Indirect Welded)Nozzle GasketsSS316L SWSF?To be ConfirmedüTo be Confirmedü Cladding on nozzles and flanges upto wetted height SS316L?To be ConfirmedTo be Confirmedü Vessel shall meet NACE MR0175 & ISO 15156 As per Data Sheet & Spec?To be ConfirmedTo be Confirmed Anode requirementsAs per Data Sheet & Spec?To be ConfirmedTo be Confirmed 4.2Vessel Internals Design & Supply of Vessel Internals ?ü Assembly of Internals?To be confirmedüTo be Confirmed?  All internal?To be confirmedüTo be confirmed? 5.0GUARANTEE Mechanical GuaranteeAs per Data Sheet & Spec?To be confirmedüProvidedü 6.0QUALITY REQUIREMENTS Material CertificationAs per datasheet?To be confirmedEN 10204 Type 3.1 / EN 10204 Type 2.2 As per Data Sheet & Spec Required by Vessel Fabricator To be Confirmed by Vessel Vendor /Internals Vendor SA 516 Gr. 70 N or Equivalent to suit Minus (-)50 Design Temperature  As per data sheet  As per code and datasheet Not Required by Vessel Fabricator By Vendor ID 1800:  4700 L T/T  Wall Thickness HeadCorrosion AllowanceJoint EfficiencyInsulation ThicknessVessel OrientationNormal Liquid VolumeVTAVTAVTA N/AVerticalVTANote 10  Doc No.: 247581721.xls.ms_office10/15/2014Page 2 of 8  CLIENTPROJECTSITE KEY   X PACKAGE TITLE: TAG NUMBER: V1010 A/B/CREQN. NUMBER: ? S.No.UNITS TECHNICAL BID EVALUATION SUMMARY INLET SEPARATOR FMC TechnologiesNational Oilwell VarcoSPECIFICATION REQUIREMENTSDESCRIPTION Welding,Testing & NDEAs per Data Sheet & SpecüYesüYesü Hydro TestAs per Data Sheet, Spec and CodeüYesüYes ? Third Party Inspection By SUPPLIER?To be confirmedüTo be confirmedü Quality SystemsRequired?Not SpecifiedüTo be confirmedü  ASME Code Stamp RequirementsRequiredü ASME (S, U, U2) where requiredüYesü PMI for Vessel CladdingRequired?To be confirmedTo be confirmed100% RTAs per Data Sheet & Spec?To be confirmedTo be confirmed UTAs per Data Sheet, Spec and Code?To be confirmedTo be confirmedMT &PTAs per Data Sheet & Spec?To be confirmedTo be confirmedImpact Test for materials AS per Code?To be confirmedTo be confirmed 7.0WEIGHT DATA Empty WeightkgVendor to specifyü23,119ü22,060ü Operating WeightkgVendor to specify?Not ProvidedNot Providedü Hydrotest WeightkgVendor to specifyü38,119Not Providedü 8.0SPARES Supply of Start-up &Commissioning SparesAs per Data Sheet & Spec?Not ProvidedüProvided? List of 2 years SparesAs per Data Sheet & Spec?Not ProvidedüNot Provided? 9.010.0DEVIATIONS Vendor to bringout all deviations specifically 11.0EXPERIENCE RECORD 12.0OVERALL TECHNICAL ACCEPTABILITY13.0TECHNICAL RANKING  Deviations if any Doc No.: 247581721.xls.ms_office10/15/2014Page 3 of 8  CLIENTPROJECTSITE KEY   X PACKAGE TITLE: TAG NUMBER: V1010 A/B/CREQN. NUMBER: ? S.No.UNITS TECHNICAL BID EVALUATION SUMMARY INLET SEPARATOR FMC TechnologiesNational Oilwell VarcoSPECIFICATION REQUIREMENTSDESCRIPTION REMARKS : Doc No.: 247581721.xls.ms_office10/15/2014Page 4 of 8

Wind Power

Jul 23, 2017

buv48a.pdf

Jul 23, 2017
Search
Similar documents
Tags
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks