General Desc ription The Tyco ® 2 thru 8 inch (DN50 thru DN200) Model PRV-1 Pressure Re- ducing Valves are factory assembled and fully trimmed valve arrangements for pressure control. They are used on water filled pipe where it is necessary to reduce a higher inlet pressure to a lower delivery pressure under static and/or residual flowing conditions. The PRV-1 is intended to automatically maintain the outlet “set pressure” (static and residual) within a clos
Categories
Published
of 16
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Related Documents
Share
Transcript
  General Description  The Tyco  ®  2 thru 8 inch (DN50 thruDN200) Model PRV-1 Pressure Re-ducing Valves are factory assembledand fully trimmed valve arrangementsfor pressure control. They are used onwater filled pipe where it is necessaryto reduce a higher inlet pressure toa lower delivery pressure under staticand/orresidualflowingconditions.ThePRV-1 is intended to automaticallymaintain the outlet “set pressure”(static and residual) within a closerange, regardless of fluctuations in thehigher pressure inlet line or varyingflow rates.The PRV-1 is provided with a factoryoutlet “set pressure” of 125 psi (8,6bar); however it may be field set to anominal outlet “set pressure” of 80 to225 psi (5,5 to 15,5 bar) per its FMApproval or 80 to 150 psi (5,5 to 10,3bar) per its UL Listing. Typical applications are as follows: ã  Within the main header (Ref. Figure1) supplying wet pipe, dry pipe, del-uge, or preaction system risers,and/or a standpipe system supply-ing hose connections. ã  As part of a sectional floor controlassembly (Ref. Figure 2) supplyingsprinkler systems, and/or hose sta-tions. Features are as follows: ã  Can be installed in any orientation. ã  Eliminates any required bleeding oftrapped air from the diaphragmchamber during installation. ã  Globe or angle pattern. ã  Accurate pressure control. ã  Standard nylon coated internal andexternal.(continued) Model PRV-1 Pressure Reducing Valve 2 thru 8 Inch (DN50 thru DN200), 250 psi (17,2 bar) Pilot Operated, Globe and Angle Body Styles  Technical Services:  Tel: (800) 381-9312 / Fax: (800) 791-5500 Page 1 of 16 TFP1580NOVEMBER, 2007 End Connection2 Inch(DN50)3 Inch(DN80)4 Inch(DN100)6 Inch(DN150)8 Inch(DN200)Nominal Valve SizeThread x ThreadGroove x GrooveGlobeFlange x Flange Available Body Styles, End Connections & Sizes N/A N/AN/AN/AN/AN/AN/AN/AThread x ThreadGroove x GrooveFlange x FlangeAngleBodyStyle= AvailableN/AN/AN/A = Not Available SOUTH AMERICA, CENTRALAMERICA & EASTERN HEMISPHERE End Connection2 Inch(DN50)3 Inch(DN80)4 Inch(DN100)6 Inch(DN150)8 Inch(DN200)Nominal Valve Size Available Body Styles, End Connections & Sizes BodyStyle NORTH AMERICA Thread x ThreadGroove x GrooveGlobeFlange x FlangeN/A N/AN/AN/A= Available N/A = Not AvailableN/AN/AN/AN/A  ã  One piece, one moving part dia-phragm. ã  In-line service. ã  One pilot valve sub-assembly pro-vides for any outlet “set pressure”,i.e., 80 to 225 psi (5,5 to 15,5 bar). WARNING  The Model PRV-1 Pressure Reducing Valves described herein must be in- stalled and maintained in compliance with this document, as well as with the applicable standards of the National Fire ProtectionAssociation,in addition to the standards of any other authori- ties having jurisdiction.  Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition.The installing contractor or sprinkler manufacturer should be contacted with any questions.Due to the flow regulating charac- teristic of this device, its impact on system hydraulics should be carefully considered, especially when retrofit- ted into existing systems. Downstream pressure adjustment is only to be performed by experi- enced personnel who understand the impact of adjusting the down- stream pressure and who take full responsibility of the readjustment from the factory setting.  The Pilot Valve is provided with a Tamper Cap,which upon removal for purposes of downstream adjustment will provide an indication that the PRV-1 may have been altered from its factory setting. Page 2 of 16 TFP1580 FIGURE 1TYPICAL MAIN HEADER APPLICATION FIGURE 2 TYPICAL SECTIONAL FLOOR CONTROL APPLICATION  MAINHEADER PRV-1HOSESTATIONSMAINDRAINDRY PIPESPRINKLERRISERWET PIPESPRINKLERRISERMAINCONTROLVALVEMAINDRAINPRV-1MAINCONTROLVALVE RELIEFVALVE HOSEVALVEPRV-1SECTIONALCONTROLVALVE SECTIONALFLOORCONTROLSECTIONALFLOORCONTROL SPRINKLERSHOSEVALVEPRV-1RELIEF VALVERELIEF VALVEZRISERMANIFOLDORZONECHECKSPRINKLERSCHECKVALVESECTIONALCONTROLVALVECHECKVALVE  Page 3 of 16TFP1580 FIGURE 3 MODEL PRV-1 PRESSURE REDUCING VALVE — ASSEMBLY—  Refer to KitDESCRIPTIONDiaphragmHex Bolt,6 Inch Valve, M16 x 453 & 4 Inch Valves,6 & 8 Inch Valves, M168 Inch Valve, M16 x 55M16 x 552 Inch Valve, M12 x 35Handhole CoverFlat Washer,2 Inch Valve, M123 & 4 Inch Valves, M16Valve BodyHex Nut, M16,4 Inch Valve Only6345NO.21. .. . . . . . . 4 CH. . 88CHCHVALVE PARTS. . . . . . .. . . . . . . . . . .. . . . . . . . . . .1 NR. . . . . .. .. .484CHCHCHQTY.11(a)NR. . 4 CH. . . . . . . . . . . . . 4 CHDiaphragm,. . . . . . . . . . . . .. . . . . . . . . . . . .. . . . . . . . . . . . .REPLACEMENT PARTS. . . . . . . . . . . . .. . . . . . . . . . . . .(a)2 Inch Valves3 Inch Valves4 Inch Valves8 Inch Valves6 Inch ValvesDESCRIPTIONNO.92-570-2-01192-570-2-01292-570-2-01392-570-2-01592-570-2-014P/N CHAMBERDIAPHRAGMINLETCAVITY4, 5, 6237 Pilot Valve . . . . . . . . . . . . 1(c)7(b) Pilot Valve . . . . . . . . . . . . . . . 92-570-2-200 INLETPRESSUREGAUGEPRESSUREGAUGEOUTLET11 . .Water Pressure Gauge8 2(d)Water Pressure Gauge(c) 92-570-2-201. . . . . 1ANGLE BODY STYLEGLOBE BODY STYLE3PRESSUREGAUGEINLETGAUGEPRESSURE24, 5, 6OUTLETDIAPHRAGMCHAMBER711 Strainer9 . . . . . . . . . . . . . . 1(e)Strainer:(d)92-570-2-202 88OUTLET CAVITY88(SEE DETAIL)STRAINERSTRAINER(SEE DETAIL) Tubing and Fitting Kit,(f)Pressure Sensor Insert10 . . 1(f) STRAINER Excludes Items 7, 8, 9, and 10Globe Style Valve:2 Inch Valve . . . . . . . . . . . . . . 92-570-3-00192-570-3-00492-570-3-00592-570-3-00392-570-3-0028 Inch Valve6 Inch Valve4 Inch Valve3 Inch Valve . . . . . . . . . . . . . .. . . . . . . . . . . . . .. . . . . . . . . . . . . .. . . . . . . . . . . . . .2 Inch Valve6 Inch Valve4 Inch Valve3 Inch ValveAngle Style Valve:. . . . . . . . . . . . . .. . . . . . . . . . . . . .. . . . . . . . . . . . . .. . . . . . . . . . . . . .Fits Either Body Style,Includes Item 2 only: GLOBE ANGLEOUTLET FLOW OUTLET FLOWTAB IS ORIENTEDDIAPHRAGMPERPENDICULAR TOOUTLET FLOW Tubing and Fittings11 . . . . . 1(e) Pressure Sensor Insert:92-571-3-00492-571-3-00392-571-3-00292-571-3-001 PRESSURE SENSORDETAILINSERT DETAIL 92-570-2-20492-570-2-20592-570-2-20792-570-2-20692-570-2-203. . . . . . . . . . . . . .. . . . . . . . . . . . . .. . . . . . . . . . . . . .. . . . . . . . . . . . . .. . . . . . . . . . . . . .3 Inch Valve4 Inch Valve6 Inch Valve8 Inch Valve2 Inch Valve (SEE DETAIL)SENSOR INSERTPRESSURE(SEE DETAIL)SENSOR INSERTPRESSURE1 2, 3, & 4 Inch Valves6 & 8 Inch Valves. . . . . . .. . . . . . . . . . 92-570-2-209(b) NOTES:NR - Not ReplaceableCH - Common Hardware1.2.DOWNSTREAMUPSTREAMDOWNSTREAMVALVEBODYTOTRIMCAVITYINTERIOROF OUTLET10SENSORINLET FACESINTERIORVALVEBODYTOTRIMOF INLET9CAVITYDOWNSTREAMOUTLET CAVITYINLET CAVITYUPSTREAMDOWNSTREAM DOWNSTREAM  Technical Data  Approvals: UL Listed. FM Approved.The UL Listing is based on ã  Installation requirements refer-enced in the Standard for Installa-tion of Sprinkler Systems, NFPA13, or the Standard for Installationof Standpipe and Hose Valves,NFPA 14, as applicable. ã  Inspection, testing, and mainte-nance requirements referenced inthe Standard for Inspection, Test-ing, and Maintenance of Water-Based Fire Protection Systems,NFPA 25. ã  The Model PRV-1 being field settoprovide the required outlet pres-sures and flows for the given appli-cation. ã  The Model PRV-1 being tested af-ter installation in accordance withNFPA 13 and/or NFPA 14 as appli-cable. ã  The Model PRV-1 being tested pe-riodically thereafter in accordancewith NFPA 25. Maximum Inlet Pressure: 250 psi (17,2 bar) Factory Outlet “Set Pressure”: 125 psi (8,6 bar) Field Outlet “Set Pressure” Range: 80 to 225 psi (5,5 to 15,5 bar) per itsFM Approval, or 80 to 150 psi (5,5 to10,3 bar) per its UL Listing Pressure Loss With Inlet PressureAbove Set Pressure The inlet pressure minus the outlet set pressure equals pressure loss.For example:assumimgthattheinletflowing pressure is 225 psi (15,5 bar)and the field outlet set pressure is130 psi (9,0 bar), the pressure lossis 95 psi (6,5 bar). Pressure Loss with Inlet PressureBelow “Set Pressure” Refer to Graphs A thru E. (Thesegraphs are a requirement of UL andshould be used as reference only.) Rated Flowing Range:2 inch (DN50):  0 to 250 GPM(0 to 946 LPM) 3 inch (DN80):  0 to 550 GPM(0 to 2080 LPM) 4 inch (DN100):  0 to 1000 GPM(0 to 3785 LPM) 6 inch (DN150):  0 to 2200 GPM(0 to 8325 LPM) 8 inch (DN200):  0 to 4000 GPM(0 to 15140 LPM) End Connections: Threaded end connections are avail-able NPT threaded or threaded perISO 7/1. Flanged end connectionsare available drilled per Table A.Grooved end connections are per in-dustry standard groove specifica-tions. Construction (Ref. Figure 3):Body.  Rilsan* blue coated ductileiron per ASTM A536-77, Grade 65-45-12. Handhole Cover.  Rilsan* bluecoated ductile iron per ASTM A536-77, Grade 65-45-12. Diaphragm . Nylon fabric reinforced,natural rubber per ASTM D2000. Diaphragm Cover Fasteners.  Gal-vanized carbon steel. Pilot Valve.  Brass and stainlesssteel with nylon fabric reinforced,natural rubber per ASTM D2000 dia-phragm. Strainer . Brass and stainless steel. Pressure Gauges.  2-1/2 inch (65mm) diameter, stainless steel case,0 to 350 psi (25 bar). Tube, Fittings, and Needle Valve. Copper, brass, and stainless steel.*Rilsan is a registered trademark ofATOFINA Chemicals, Inc. (The Ril-san coating is a polyamide (Nylon11) coating.) Page 4 of 16 TFP1580 TABLE ADIMENSIONAL SPECIFICATION FOR SELECTION OF FLANGE DRILLING  Same drilling as for BS 4504 Section 3.2 (PN16) and DIN 2532 (PN16).ANSI B16.1 AS 2129ISO 7005-2 JIS B 2210(Class 125) (Table E)(PN10) (10K) 2 A7.509.50(190,5)(241,3)B0.750.88(19,0)(22,2)7.009.25(178,0)(235,0)0.710.87(18,0)(22,0)6.89(175,0)Flange Drilling SpecificationNominal Dimensions in Inches and (mm)9.45(240,0)11.75(298,5)0.88(22,2)11.50(292,0)0.87(22,0)11.61(295,0)0.75(19,0)0.91(23,0)Valve4 Inch6 Inch(DN100)(DN150)8 Inch(DN200)3 Inch(DN80)N4888A B N8ISO 7005-2(PN16)7.099.45(180,0)(240,0)11.61(295,0)A B N88812ISO 7005-2(PN16)USEA B N88A B N888Dim. Dim.NominalQty. Dim. Dim. Qty. Dim. Dim. Qty. Dim. Dim. Qty. Dim. Dim. Qty.Same drilling as for BS 4504 Section 3.2 (PN10) and DIN 2532 (PN10).Dim.ABolt CircleDiameterDim. BBolt HoleDiameterQty. NNumber ofBolt Holes 323 6.00(152,4)6.30(160,0)SizeSame drilling as forANSI B16.5 (Class 150) and ANSI B16.42 (Class 150). 11 0.75(19,0)0.75(19,0)0.91(23,0)0.91(23,0)0.59(15,0) 8 40.71(18,0)5.75(146,0)5.90(150,0)0.75(19,0)11.42(290,0) 120.75(19,0)0.59(15,0)
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks